IG541混合氣(qi)體(ti)(ti)滅(mie)火劑(ji)是(shi)一種(zhong)無色、無味、無毒(du)、不(bu)導電的(de)(de)壓(ya)縮氣(qi)體(ti)(ti),它(ta)由52%氮、40%氬、8%二氧化碳三(san)種(zhong)氣(qi)體(ti)(ti)組(zu)成,滅(mie)火過程中不(bu)影響人(ren)的(de)(de)視野且(qie)不(bu)產生(sheng)溫差和腐蝕性分解物,臭氧耗(hao)損潛能值ODP=0,溫室效應潛能值GWP=0,其在(zai)大氣(qi)中存留的(de)(de)時間(jian)很(hen)短,是(shi)一種(zhong)綠色環(huan)保型滅(mie)火劑(ji),適用在(zai)經常有人(ren)工作的(de)(de)場(chang)所。
IG541混合氣體滅火設備----特點
IG541氣體滅(mie)(mie)火設(she)(she)(she)備與自(zi)動(dong)(dong)(dong)報(bao)警控(kong)制(zhi)設(she)(she)(she)備相聯,可組成(cheng)單(dan)元獨立設(she)(she)(she)備或(huo)組合分配設(she)(she)(she)備,實施對(dui)單(dan)區或(huo)分區的保護(hu)。本設(she)(she)(she)備與自(zi)動(dong)(dong)(dong)報(bao)警控(kong)制(zhi)設(she)(she)(she)備相連接,具(ju)有自(zi)動(dong)(dong)(dong)滅(mie)(mie)火功(gong)能(neng)(neng),在(zai)緊(jin)急情況下還可利用電氣手動(dong)(dong)(dong)啟動(dong)(dong)(dong)或(huo)機械應急手動(dong)(dong)(dong)方式啟動(dong)(dong)(dong)滅(mie)(mie)火設(she)(she)(she)備,具(ju)有動(dong)(dong)(dong)能(neng)(neng)完善(shan)、自(zi)動(dong)(dong)(dong)性能(neng)(neng)良(liang)好、工作準確可靠、操(cao)作維護(hu)方便(bian)等特點。
IG541混合(he)氣體滅(mie)火設備----使用范圍(wei)
IG541混合氣(qi)(qi)體滅火(huo)設(she)備適(shi)用(yong)于:A類(lei)表(biao)面火(huo)災(zai)(zai)及部分(fen)固(gu)體(如棉花(hua)、紙(zhi)張)深位火(huo)災(zai)(zai);B類(lei)易燃液體火(huo)災(zai)(zai)或可熔化固(gu)體(如石蠟、瀝青)火(huo)災(zai)(zai);C類(lei)滅火(huo)前能切斷氣(qi)(qi)源的(de)氣(qi)(qi)體火(huo)災(zai)(zai),如甲烷、乙烷、城市煤氣(qi)(qi)等(deng);E類(lei)電器設(she)備火(huo)災(zai)(zai),如變壓(ya)器、開(kai)關、發電機(ji)、電動機(ji)等(deng)。但(dan)不用(yong)于撲救D類(lei)活潑金(jin)屬火(huo)災(zai)(zai)。
由一套(tao)滅火劑瓶組對應一套(tao)管(guan)網設備,保護一個防護區(qu)所組成的設備形(xing)式。
單元獨立(li)設(she)備由滅(mie)火(huo)劑瓶(ping)組(zu)、瓶(ping)組(zu)支架、液(ye)體(ti)單向閥、金屬軟管(guan)(guan)(guan)、集流管(guan)(guan)(guan)、驅動(dong)氣體(ti)瓶(ping)組(zu)、減壓裝(zhuang)置、低泄(xie)高封(feng)閥、啟動(dong)管(guan)(guan)(guan)路、安全泄(xie)放裝(zhuang)置、噴嘴、管(guan)(guan)(guan)網設(she)備等組(zu)成。
2、 組(zu)合分配設備
由(you)一套(tao)滅(mie)火(huo)劑瓶(ping)組對應幾(ji)套(tao)管(guan)網設(she)備,保護兩個(ge)或(huo)兩個(ge)以上的防護區所組成(cheng)的設(she)備形式。組合(he)分配設(she)備由(you)滅(mie)火(huo)劑瓶(ping)組、瓶(ping)組支架(jia)、液(ye)體單向閥(fa)、金屬軟管(guan)、集(ji)流管(guan)、驅動氣體瓶(ping)組、減壓裝置、低泄(xie)高(gao)封閥(fa)、啟動管(guan)路、安全(quan)泄(xie)放(fang)裝置、噴嘴、管(guan)網設(she)備等組成(cheng)。
IG541混合(he)氣體滅(mie)火(huo)設備----滅(mie)火(huo)原理
(1)自(zi)動(dong)控(kong)制(zhi)(zhi)方式(shi):本(ben)滅火(huo)(huo)控(kong)制(zhi)(zhi)器(qi)配有(you)感(gan)煙火(huo)(huo)災(zai)探(tan)測(ce)(ce)器(qi)和定溫式(shi)感(gan)溫火(huo)(huo)災(zai)探(tan)測(ce)(ce)器(qi)。正常(chang)狀態(tai)下,氣(qi)體(ti)(ti)滅火(huo)(huo)控(kong)制(zhi)(zhi)器(qi)的(de)控(kong)制(zhi)(zhi)方式(shi)選擇在“自(zi)動(dong)”位置(zhi)。當(dang)保護(hu)區發(fa)生火(huo)(huo)情(qing),火(huo)(huo)災(zai)探(tan)測(ce)(ce)器(qi)發(fa)出火(huo)(huo)警信號(hao),火(huo)(huo)災(zai)報(bao)警滅火(huo)(huo)控(kong)制(zhi)(zhi)器(qi)(或氣(qi)體(ti)(ti)滅火(huo)(huo)控(kong)制(zhi)(zhi)器(qi))即(ji)(ji)發(fa)出聲、光報(bao)警信號(hao),同(tong)時(shi)發(fa)出聯動(dong)命令(ling)(ling),關(guan)閉空調、風機、防火(huo)(huo)卷簾等通風設(she)備,經(jing)過0-30秒(miao)延時(shi)(此時(shi)防護(hu)區內人員必須(xu)迅(xun)速(su)撤離),輸出DC24V/1.5A滅火(huo)(huo)電源信號(hao)驅動(dong)啟(qi)動(dong)瓶(ping)電磁型驅動(dong)裝置(zhi),釋(shi)放(fang)出的(de)控(kong)制(zhi)(zhi)氣(qi)體(ti)(ti)打開對應保護(hu)區的(de)選擇閥,繼而打開滅火(huo)(huo)劑(ji)瓶(ping)組上的(de)容器(qi)閥,釋(shi)放(fang)IG541滅火(huo)(huo)劑(ji)實施滅火(huo)(huo)。如在報(bao)警過程中(zhong)發(fa)現不需要啟(qi)動(dong)滅火(huo)(huo)裝置(zhi),可按下保護(hu)區外的(de)或控(kong)制(zhi)(zhi)操作(zuo)面板上的(de)“緊急停止按扭”,即(ji)(ji)可終止控(kong)制(zhi)(zhi)滅火(huo)(huo)指令(ling)(ling)的(de)發(fa)出。
(2)手動(dong)控制方(fang)式:將氣體滅火(huo)(huo)(huo)(huo)(huo)控制器(qi)(qi)的(de)控制方(fang)式選擇在“手動(dong)”位置(zhi)時,滅火(huo)(huo)(huo)(huo)(huo)控制器(qi)(qi)處于手動(dong)控制狀態(tai)。這時,當火(huo)(huo)(huo)(huo)(huo)災(zai)探測器(qi)(qi)發(fa)出(chu)火(huo)(huo)(huo)(huo)(huo)警(jing)信(xin)(xin)號(hao)(hao)時,控制器(qi)(qi)即發(fa)出(chu)火(huo)(huo)(huo)(huo)(huo)災(zai)聲、光報(bao)警(jing)信(xin)(xin)號(hao)(hao),而不啟動(dong)滅火(huo)(huo)(huo)(huo)(huo)裝(zhuang)(zhuang)置(zhi),需經人(ren)員觀察,確(que)認火(huo)(huo)(huo)(huo)(huo)災(zai)已發(fa)生時,可(ke)按下保(bao)護區外或控制器(qi)(qi)操作面板上的(de)“緊急啟動(dong)按鈕”,即可(ke)啟動(dong)滅火(huo)(huo)(huo)(huo)(huo)裝(zhuang)(zhuang)置(zhi),釋放IG541滅火(huo)(huo)(huo)(huo)(huo)劑實施(shi)滅火(huo)(huo)(huo)(huo)(huo)。但報(bao)警(jing)信(xin)(xin)號(hao)(hao)仍(reng)存在。
無論裝(zhuang)(zhuang)置(zhi)處(chu)于自動或手(shou)動狀態,按緊(jin)急啟動按扭,都可(ke)啟動滅(mie)(mie)(mie)火(huo)裝(zhuang)(zhuang)置(zhi),釋(shi)放IG541滅(mie)(mie)(mie)火(huo)劑實施滅(mie)(mie)(mie)火(huo);同時控制器立即進入(ru)滅(mie)(mie)(mie)火(huo)報警狀態。
(3)機械應急(ji)手(shou)動(dong)(dong)(dong)控制方(fang)式(shi):用于控制器(qi)失效時(shi),當職守人員(yuan)判斷為火災時(shi),應立即(ji)通(tong)知現(xian)(xian)場(chang)所(suo)有(you)人員(yuan)撤離現(xian)(xian)場(chang),在(zai)確定所(suo)有(you)人員(yuan)撤離現(xian)(xian)場(chang)后,方(fang)可按(an)以下步驟實施(shi)應急(ji)機械啟動(dong)(dong)(dong):a、手(shou)動(dong)(dong)(dong)關閉(bi)聯動(dong)(dong)(dong)設備(bei)并(bing)切斷電源。b、在(zai)設備(bei)間(jian)拔掉對應防護區(qu)驅(qu)動(dong)(dong)(dong)氣體(ti)瓶(ping)組上的(de)(de)保險環(huan),用手(shou)壓下手(shou)柄( 必須確定啟動(dong)(dong)(dong)瓶(ping)內有(you)符合要求的(de)(de)壓力),即(ji)可釋(shi)放驅(qu)動(dong)(dong)(dong)氣體(ti)驅(qu)動(dong)(dong)(dong)選擇閥、容器(qi)閥開啟,實施(shi)滅火。
滅火設備控制程序:
IG541混(hun)合氣體(ti)滅火(huo)設備----注(zhu)意(yi)事項
1)為保證產品(pin)的(de)(de)安全(quan),拔出驅(qu)動(dong)(dong)器(qi)上(shang)的(de)(de)鎖(suo)定安全(quan)銷時(shi)應注(zhu)意:為避免安裝啟動(dong)(dong)器(qi)時(shi)閥針刺破密封膜片,造成(cheng)滅火(huo)劑(ji)(ji)誤噴,先(xian)將驅(qu)動(dong)(dong)氣(qi)體瓶(ping)組與滅火(huo)劑(ji)(ji)瓶(ping)組連(lian)接(jie)(jie)的(de)(de)驅(qu)動(dong)(dong)管路(lu)(lu)斷開(kai)。設備安裝調(diao)試(shi)合格,交付(fu)使用(yong)時(shi),將啟動(dong)(dong)器(qi)上(shang)的(de)(de)安全(quan)銷拔出,連(lian)接(jie)(jie)驅(qu)動(dong)(dong)氣(qi)體瓶(ping)組與滅火(huo)劑(ji)(ji)瓶(ping)組間的(de)(de)驅(qu)動(dong)(dong)管路(lu)(lu)。
2)將(jiang)滅(mie)火控制器輸出線路(lu)(lu)與(yu)滅(mie)火裝(zhuang)置電(dian)磁型驅動裝(zhuang)置線路(lu)(lu)相連接(一般為RVS2×1.5雙絞線),滅(mie)火控制器輸出的滅(mie)火信號(hao)必須滿足DC24V/1.5A(點動式)。
3)將(jiang)滅火控制器(qi)滅火信號(hao)(hao)(hao)反(fan)饋線(xian)與(yu)信號(hao)(hao)(hao)反(fan)饋裝置線(xian)路相連接(一(yi)般(ban)為RVS2×1.5雙絞線(xian)),與(yu)信號(hao)(hao)(hao)反(fan)饋裝置相連接的(de)線(xian)路必須是無源干(gan)接點信號(hao)(hao)(hao)。
4)安裝驅動氣體儲存容器電(dian)磁型驅動裝置(zhi)時應注意:
安裝(zhuang)時(shi),首先應檢查(cha)閥(fa)(fa)針長度,避免(mian)閥(fa)(fa)針過長刺(ci)破(po)密封膜(mo)片,然后將電(dian)磁驅動(dong)器順(shun)時(shi)針方向慢慢旋(xuan)入(ru)啟動(dong)瓶閥(fa)(fa)頂部(bu),并擰緊。(注意(yi):裝(zhuang)入(ru)閥(fa)(fa)針的電(dian)磁型驅動(dong)裝(zhuang)置不要傾(qing)斜插入(ru)啟動(dong)瓶閥(fa)(fa)頂部(bu);旋(xuan)緊啟動(dong)器時(shi)應輕輕擰緊,以(yi)免(mian)刺(ci)破(po)膜(mo)片)。
5)驅(qu)動(dong)氣(qi)體貯存容器壓(ya)力表必須每(mei)年檢(jian)修,不合(he)格予以(yi)更換。
6)為了避免容器在(zai)運輸、裝卸(xie)過程(cheng)中滅火劑(ji)誤噴(pen)(pen)放,在(zai)啟(qi)動瓶閥(fa)出口處設(she)置有防(fang)護裝置,裝置上(shang)有小(xiao)孔,能使氮氣均勻噴(pen)(pen)放而不產(chan)生較(jiao)大的反沖力。如圖5所示。
7)驅動(dong)氣體貯存(cun)容器維護檢查方(fang)法:
a)檢(jian)查壓(ya)力表開(kai)關是否關閉,即開(kai)關螺塞是否旋(xuan)緊(jin),用肥皂水檢(jian)查接點是否有氣泡。
b)關閉壓(ya)力(li)表(biao)(biao)開關,卸下壓(ya)力(li)表(biao)(biao)檢查壓(ya)力(li)表(biao)(biao)指(zhi)針是否回零,否則(ze)更換壓(ya)力(li)表(biao)(biao)。
c)壓力(li)表顯示(shi)壓力(li)低于5.6MPa時,應重新充裝(zhuang)氮氣至6.0MPa。
8)在手動(dong)操(cao)作時,一定要拔下驅動(dong)氣體瓶組電磁啟動(dong)裝置的緊急啟動(dong)銷(xiao)。
檢測驅動氣體瓶組壓力
為了使裝置保持良(liang)好的(de)狀態,確(que)保瓶(ping)組(zu)壓(ya)(ya)(ya)(ya)力(li)(li)正(zheng)常,在發(fa)生火(huo)災(zai)時(shi)(shi)能迅速的(de)投入使用(yong),由用(yong)戶(hu)經過專門培訓的(de)專職或(huo)兼職人員(yuan)進行必需的(de)定期檢(jian)測滅火(huo)劑(ji)瓶(ping)組(zu)壓(ya)(ya)(ya)(ya)力(li)(li)。檢(jian)測滅火(huo)劑(ji)瓶(ping)組(zu)壓(ya)(ya)(ya)(ya)力(li)(li)時(shi)(shi),用(yong)活動扳手(shou)卡死充裝接嘴的(de)六邊形(xing)螺母,緩(huan)慢(man)逆時(shi)(shi)針(zhen)旋轉(zhuan)90°,壓(ya)(ya)(ya)(ya)力(li)(li)表(biao)指針(zhen)所(suo)示壓(ya)(ya)(ya)(ya)力(li)(li)即(ji)為瓶(ping)組(zu)內部壓(ya)(ya)(ya)(ya)力(li)(li),視(shi)線正(zheng)對壓(ya)(ya)(ya)(ya)力(li)(li)表(biao),讀取壓(ya)(ya)(ya)(ya)力(li)(li)表(biao)值并記錄,然后將螺母緩(huan)慢(man)順時(shi)(shi)針(zhen)旋轉(zhuan)90°,卸去表(biao)內壓(ya)(ya)(ya)(ya)力(li)(li);壓(ya)(ya)(ya)(ya)力(li)(li)表(biao)指針(zhen)如(ru)低于5.6MPa時(shi)(shi)要重新(xin)充裝滅火(huo)劑(ji)。壓(ya)(ya)(ya)(ya)力(li)(li)表(biao)順時(shi)(shi)針(zhen)復位緊固,為下次檢(jian)查作準備。